Software · Foundation · ½ day

CeraPID — User Training

Hands-on course for loop assessment and model-based tuning in CeraPID

Duration½ day
LevelFoundation
FormatOn-site · virtual
CodeTR-H07
CeraPHA Studio · Node 7 · HAZOP GuidewordCauseSafeguardMORE flowFCV fails openPSV-201 · SISNO flowPump tripLAL-210 alarm IPL credited ✓
Course flyer

CeraPID — User Training — one-page catalogue.

The flyer below is the printable A4 version. Use the buttons above to download it or the request form.

CeraPID — User Training — one-page course flyer
Click the flyer to open the printable PDF.
Request this courseDownload the Training Request Form, quote course code TR-H07, sign and e-mail it to sales@cerasus.ai — or use the consultation form below.
Download Training Request Form →
At a glance

What you will be able to do.

Control and instrument engineers, process control specialists, console supervisors and administrators who will use or manage CeraPID

A short, hands-on course that takes a control engineer from installation to a retuned loop: connecting to the historian, importing the loop inventory, running the plant-wide loop assessment, reading the KPIs and valve diagnostics, identifying a process model from step or closed-loop data and calculating IMC/lambda tuning with a documented change record. Administrators cover historian connections, DCS tag mapping and user roles.

  • Configure historian and DCS connections and import the loop inventory
  • Run the plant-wide loop assessment and rank loops by performance and impact
  • Interpret loop KPIs: oscillation, variability, saturation and stiction
  • Identify a process model from historical or step-test data
  • Calculate and document IMC/lambda tuning and simulate the response
  • Administer users, tag mapping and assessment schedules
Course outline

Day by day

Session 1

Installation and editions · historian and DCS connections · loop inventory and tag mapping · plant-wide assessment and KPI dashboard · valve diagnostics and stiction detection

Session 2

Model identification from step and closed-loop data · IMC/lambda tuning and simulation · tuning reports and change records · export to MOC · administration · Q&A on participants' own loops

Standards referenced
ISA-5.1
ANSI/ISA-75.25.01 (Control Valve Response)
ISA-TR75.25.02
IEC 61131-3
Request a consultation

Tell us about the unit and the problem.

Send a short brief — plant, service of interest and what you need to achieve — and a Cerasus engineer will respond with a proposed scope and next steps.

Prefer email or phone? sales@cerasus.ai · +974 5506 2743